PV Inverters

Residential

The ASP Grid-Tied PV Inverter’s offer market leading efficiency and voltage
operating range which maximizes energy yield and return on investment for
consumers. Installation time and costs are greatly reduced through integrating
the combiner box, AC/DC disconnects, and wire raceway. The design also
simplifies service on the unit through a 2-piece modular configuration which
allows the wiring box to remain connected and mounted if in the event you need
to replace the power module.

• Broad voltage operating range (105-500 Vdc) for superior performance in low
light and high temperature environments

• Integrated PV system AC / DC disconnect switch saves installation time and cost




Ratings

  • 3800W, 4000W, 5000W, 6000W, 7000W

Maximum Energy Harvest

  • 97% CEC efficiency
  • Broad voltage operating range (105-500 Vdc) for superior performance in low light and high temperature environments
  • Transformerless design

Saves Installation Time & Cost

  • Integrated PV system AC / DC disconnect switch
  • (4) branch circuit-rated negative and positive fused inputs
  • Integrated NEC® compliant wire raceway

Versatility in Installation

  • Field selectable voltage output: 208/240/277 Vac
  • LCD display with nighttime monitoring capabilities.
  • NEMA 3R enclosure
  • 2-piece modular design


ModelPV240PV250PV260PV270
Nominal Power Output3800W | 4000W5000W6000W7000W
Dimension WxHxD (in.)17.1 x 33.3 x 8.317.1 x 33.3 x 8.3 in17.1 x 33.3 x 8.3 in V17.1 x 33.3 x 8.3 in
Gross Weight86 lbs | 86 lbs90 lbs101 lbs101 lbs
Input (DC side)Internal Combiner
/ Multi-string
Max. number of strings4444
Terminal block(+)×4, (-)×4, (G)×1(+)×4, (-)×4, (G)×1(+)×4, (-)×4, (G)×1(+)×4, (-)×4, (G)×1
Admissible conductor size14 ~ 6 AWG14 ~ 6 AWG14 ~ 6 AWG14 ~ 6 AWG
External Combiner
/ Single string
Bypass fuse terminal block(+)×1, (-)×1, (G)×1(+)×1, (-)×1, (G)×1(+)×1, (-)×1, (G)×1(+)×1, (-)×1, (G)×1
Maximum admissible
conductor size
4 AWG4 AWG4 AWG4 AWG
Output (AC side)Terminal blockTerminal block labeled with 1, 2, 3 and GTerminal block labeled with 1, 2, 3 and GTerminal block labeled with 1, 2, 3 and GTerminal block labeled with 1, 2, 3 and GTerminal block labeled with 1, 2, 3 and G
Admissible conductor size10 ~ 6 AWG10 ~ 6 AWG10 ~ 6 AWG10 ~ 6 AWG10 ~ 6 AWG


Diagram dimensions are in millimeters.


ModelPV240PV250PV260PV270
Input (DC)
Nominal DC voltage360 V360 V360 V360 V
Max. DC voltage600 V600 V600 V600 V
System start-up voltage150 V150 V150 V150 V
Shutdown voltageTypical 80VTypical 80VTypical 80VTypical 80V
MPPT voltage range105 - 500 V105 - 500 V105 - 500 V105 - 500 V
Full rating voltage range225 - 500 V225 - 500 V225 - 500 V225 - 500 V
Max. DC current19A26A32A37A
Number of DC input terminals4444
Output (AC)
Nominal AC power @ 240Vac & 277Vac3800W | 4000W5000W6000W7000W
Nominal AC power @ 208Vac3800W | 4000W4600W6000W7000W
Max. AC power @ 240Vac & 277Vac3800W | 4000W5000W6000W7000W
Max. AC power @ 208Vac3800W | 3800W4600W6000W7000W
Nominal AC voltage208V / 240V / 277V208V / 240V / 277V208V / 240V / 277V208V / 240V / 277V
Nominal frequency60Hz60Hz60Hz60Hz
Disconnection time of excess operational frequency range<0.16 sec<0.16 sec<0.16 sec<0.16 sec
Nominal AC current @ 208Vac18.3 A | 18.3 A22.1 A28.9 A33.7 A
Nominal AC current @ 240Vac15.8 A | 16.7 A20.8 A25.0 A29.2 A
Nominal AC current @ 277Vac13.7 A | 14.4 A18.1 A21.7 A25.3 A
Max. AC current @ 208Vac18.3 A | 18.5 A22.5 A30.0 A35.0 A
Max. AC current @ 240Vac15.8 A | 18.5 A22.5 A28.5 A33.2 A
Max. AC current @ 277Vac13.7 A | 16.4 A20.5 A24.6 A28.7 A
Power Factor> 0.99> 0.99> 0.99> 0.99
Efficiency
Peak efficiency97.5%97.5%97.5%97.5%
CEC efficiency97%97%97%97%
General Data
TopologyTransformerlessTransformerlessTransformerlessTransformerless
Dimensions (W / H / D) inches17.1 / 33.3 / 8.317.1 / 33.3 / 8.317.1 / 33.3 / 8.317.1 / 33.3 / 8.3
Weight (lbs)8690101101
Power consumption: standby / night< 7W / < 0.2W< 7W / < 0.2W< 7W / < 0.2W< 7W / < 0.2W
DC insulation resistance> 4MΩ> 4MΩ> 4MΩ> 4MΩ
EnclosureNEMA 3RNEMA 3RNEMA 3RNEMA 3R
Heat dissipationForce air cooling, variable fan speed according to temperature on heat sink
Operating temperature range-25 – +50oC-25 – +50oC-25 – +50oC-25 – +50oC
Humidity0 to 95%, non-condensing0 to 95%, non-condensing0 to 95%, non-condensing0 to 95%, non-condensing
CommunicationRS232 / Super-485RS232 / Super-485RS232 / Super-485RS232 / Super-485
Ground fault protectionInternal GFCI and Isolation detection function, in accordance with UL 1741
DisconnectIntegrated AC & DC SwitchIntegrated AC & DC SwitchIntegrated AC & DC SwitchIntegrated AC & DC Switch
CertificationsETL (in compliance with UL1741), CEC (in progress)
DC Surge protection4kV4kV4kV4kV
AC Surge protection6kV6kV6kV6kV


Diagram dimensions are in millimeters.